APC SMT1000IC uninterruptible power supply (UPS) Line-Interactive 1 kVA 700 W 8 AC outlet(s)
Part number:
SMT1000IC
EAN:
731304332978
> Line-Interactive
> 1 kVA 700 W
> Waveform: Sine
> 8 AC outlet(s)
> Sealed Lead Acid (VRLA)
> Mini Tower Black
Description
APC SMT1000IC. UPS topology: Line-Interactive, Output power capacity: 1 kVA, Output power: 700 W. AC outlet types: C13 coupler, IEC Jumpers, Power plug: C14 coupler, AC outlets quantity: 8 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Battery life (max): 5 year(s), Battery recharge time: 3 h. Form factor: Mini Tower, Product color: Black, Display type: LCD. Width: 6.73" (171 mm), Depth: 17.3" (439 mm), Height: 8.62" (219 mm)
Specifications
Features
UPS topology
![The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. UPS topology](https://gfx.senetic.com/gfx/help_new.png)
Line-Interactive
Output power capacity
![The maximum power that the device can produce. Output power capacity](https://gfx.senetic.com/gfx/help_new.png)
1 kVA
Output power
![The power that the device can produce. Output power](https://gfx.senetic.com/gfx/help_new.png)
700 W
Waveform
Sine
Input operation voltage (min)
![The minumum voltage needed by the device during operation. Input operation voltage (min)](https://gfx.senetic.com/gfx/help_new.png)
151 V
Input operation voltage (max)
![The maximum input voltage supported by the device. Input operation voltage (max)](https://gfx.senetic.com/gfx/help_new.png)
302 V
Input frequency
![The frequency (Hz) which is required to power the product. Input frequency](https://gfx.senetic.com/gfx/help_new.png)
50/60 Hz
Output operation voltage (min)
![The minumum voltage produced by the device during operation. Output operation voltage (min)](https://gfx.senetic.com/gfx/help_new.png)
220 V
Output operation voltage (max)
![The maximum output voltage produced by the device. Output operation voltage (max)](https://gfx.senetic.com/gfx/help_new.png)
240 V
Output frequency
50/60 Hz
Automatic Voltage Regulation (AVR)
Yes
Surge energy rating
![A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. Surge energy rating](https://gfx.senetic.com/gfx/help_new.png)
459 J
Response time
![The response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.) Response time](https://gfx.senetic.com/gfx/help_new.png)
10 ms
Output voltage Total Harmonic Distortion (THD)
5%
Noise level
![The amplitude level of the undesired background noise, usually measured in decibels (db). Noise level](https://gfx.senetic.com/gfx/help_new.png)
41 dB
Surge protection
Yes
Audible alarm(s)
![Alarms that make a sound when they are activated (set off). Audible alarm(s)](https://gfx.senetic.com/gfx/help_new.png)
Yes
Audible alarm modes
Alarm when on battery, Low battery alarm, Overload alarm
Auto-restart
Yes
Temperature voltage compensation
Yes
Ports & interfaces
AC outlet types
![The type of outlet for AC electricity. AC outlet types](https://gfx.senetic.com/gfx/help_new.png)
C13 coupler, IEC Jumpers
Power plug
![A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. Power plug](https://gfx.senetic.com/gfx/help_new.png)
C14 coupler
AC outlets quantity
![The number of sockets in the device where AC electrical power can be connected. AC outlets quantity](https://gfx.senetic.com/gfx/help_new.png)
8 AC outlet(s)
USB port
![The device features a socket into which a USB cable can be plugged. USB port](https://gfx.senetic.com/gfx/help_new.png)
Yes
USB port type
USB Type-A
USB 2.0 ports quantity
![Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called USB 2.0 ports quantity](https://gfx.senetic.com/gfx/help_new.png)
1
Serial interface
Yes
Serial ports quantity
![The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term Serial ports quantity](https://gfx.senetic.com/gfx/help_new.png)
1
Ethernet LAN (RJ-45) ports
![Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet. Ethernet LAN (RJ-45) ports](https://gfx.senetic.com/gfx/help_new.png)
1
SmartSlot
Yes
Battery
Battery technology
![The type of battery in the device, e.g. nickel–cadmium (NiCd). Battery technology](https://gfx.senetic.com/gfx/help_new.png)
Sealed Lead Acid (VRLA)
Battery life (max)
5 year(s)
Battery recharge time
![Approximate time required to recharge the battery from completely empty to completely full Battery recharge time](https://gfx.senetic.com/gfx/help_new.png)
3 h
Hot-swap battery
Yes
Automatic battery test
Yes
Cold start
Yes
Replacement battery cartridge
RBC6
Design
Form factor
![The shape or design of the product. Form factor](https://gfx.senetic.com/gfx/help_new.png)
Mini Tower
Product colour
![The colour e.g. red, blue, green, black, white. Product colour](https://gfx.senetic.com/gfx/help_new.png)
Black
Display type
![Type of display (screen) e.g. LCD. Display type](https://gfx.senetic.com/gfx/help_new.png)
LCD
LED indicators
Yes
Certification
CE, CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, UL 1778, VDE, REACH
Operational conditions
Operating temperature (T-T)
![The minimum and maximum temperatures at which the product can be safely operated. Operating temperature (T-T)](https://gfx.senetic.com/gfx/help_new.png)
0 - 40 °C
Storage temperature (T-T)
![The minimum and maximum temperatures at which the product can be safely stored. Storage temperature (T-T)](https://gfx.senetic.com/gfx/help_new.png)
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m
Technical details
Compliance certificates
RoHS
Sustainability certificates
Green Premium
Weight & dimensions
Width
![The measurement or extent of something from side to side. Width](https://gfx.senetic.com/gfx/help_new.png)
171 mm
Depth
![The distance from the front to the back of something. Depth](https://gfx.senetic.com/gfx/help_new.png)
439 mm
Height
![The measurement of the product from head to foot or from base to top. Height](https://gfx.senetic.com/gfx/help_new.png)
219 mm
Weight
![Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. Weight](https://gfx.senetic.com/gfx/help_new.png)
18.9 kg
Package width
![The distance from one side of the packaging to the other. Package width](https://gfx.senetic.com/gfx/help_new.png)
328 mm
Package depth
![The distance from the front to the back of the packaging. Package depth](https://gfx.senetic.com/gfx/help_new.png)
595 mm
Package height
![The distance from the top to the bottom of the packaging. Package height](https://gfx.senetic.com/gfx/help_new.png)
376 mm
Package weight
![Weight of the packaged product. Package weight](https://gfx.senetic.com/gfx/help_new.png)
22.8 kg
Packaging data
Cables included
RJ-45, USB cable
Quick installation guide
Yes
Logistics data
Products per pallet
![Quantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet. Products per pallet](https://gfx.senetic.com/gfx/help_new.png)
12 pc(s)
Harmonized System (HS) code
85078000
SKU:
1001847
Empty field
Incorrect format
Incorrect format