Cisco Catalyst IE3300 Managed L2 10G Ethernet (100/1000/10000) Black

EAN: 0889728140171
Part number: IE-3300-8P2S-E
KSh 845,217.36 net
KSh 980,452.14 gross
Availability:
1  pcs
1
1 2 3 4 5 6 7 8 9+
Payment methods
Delivery methods

Cisco Catalyst IE3300 Managed L2 10G Ethernet (100/1000/10000) Black

EAN:

0889728140171

Part number:

IE-3300-8P2S-E

Switch type: Managed
Switch layer: L2
Quality of Service (QoS) support: Yes
ARP inspection: Yes
System event log: Yes
MIB support: 802.1X MIB, CISCO-DHCP-SNOOPING-MIB, CISCO-UDLDP-MIB, CISCO-ENVMON-MIB, CISCO-PRIVATE-VLAN-MIB, CISCO-PAE-MIB, Cisco-Port-QoS-MIB, CISCO-ERR-DISABLE-MIB, CISCO- PROCESS-MIB, LLDP-MIB, CiscoMACNotification-MIB, CISCO-CONFIG-COPY-MIB, LLDP-MED-MIB, Bridge-MIB, CISCO-CAR-MIB, CISCO-LAG-MIB, CISCO-SYSLOG-MIB, CISCO-FTP-CLIENT-MIB, CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, Cisco-REP-MIB, CISCO-PORT-STORM-CONTROL-MIB, CISCO-CDP-MIB, CISCO-IP-STAT-MIB, CISCO-LICENSE-MGMT-MIB, CISCO-STP-EXTN-MIB, CISCO-VTP-MIB, IEEE8023-LAG-MIB, SMON-MIB, CISCO-ACCESS-ENVMON-MIB, CISCO-CALLHOME-MIB, CISCO-CONFIG-MAN-MIB, CISCO-FLASH-MIB, CISCO-ENTITY-SENSOR-MIB, IP-MIB, CISCO-PAGP-MIB
Basic switching RJ-45 Ethernet ports quantity: 8
Basic switching RJ-45 Ethernet ports type: 10G Ethernet (100/1000/10000)
Console port: RJ-45
Power connector: AC-in jack
show more
Ideal solutions for your business
We find the optimal solution for your business. Our sales and presales specialists select products and services for our customers every day.
Express delivery of equipment worldwide
We guarantee on-time delivery of your equipment wherever you are. We work with global partners to ensure our logistics are optimised.
Implementation support guaranteed
We offer support in implementing solutions in your business. Our qualified engineers help you manage your infrastructure effectively.
Customer first
Our RMA experts deal with complaints and equipment replacements quickly and efficiently, so that your business can run smoothly.
Description
Read more about Cisco Catalyst IE3300 Managed L2 10G Ethernet (100/1000/10000) Black
Specifications
Management features
What switch device has, managed or unmanaged.  Switch type Managed  
A network switch is a computer networking device that links networking segments. A switch has different layers, such as layer 2 (a network bridge, operating at the data link layer, interconnecting a small number of devices) and layer 4 (can act as a firewall, amongst other things).  Switch layer L2  
Quality of Service (QoS) support Yes  
ARP inspection Yes  
System event log Yes  
MIB support 802.1X MIB, CISCO-DHCP-SNOOPING-MIB, CISCO-UDLDP-MIB, CISCO-ENVMON-MIB, CISCO-PRIVATE-VLAN-MIB, CISCO-PAE-MIB, Cisco-Port-QoS-MIB, CISCO-ERR-DISABLE-MIB, CISCO- PROCESS-MIB, LLDP-MIB, CiscoMACNotification-MIB, CISCO-CONFIG-COPY-MIB, LLDP-MED-MIB, Bridge-MIB, CISCO-CAR-MIB, CISCO-LAG-MIB, CISCO-SYSLOG-MIB, CISCO-FTP-CLIENT-MIB, CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, Cisco-REP-MIB, CISCO-PORT-STORM-CONTROL-MIB, CISCO-CDP-MIB, CISCO-IP-STAT-MIB, CISCO-LICENSE-MGMT-MIB, CISCO-STP-EXTN-MIB, CISCO-VTP-MIB, IEEE8023-LAG-MIB, SMON-MIB, CISCO-ACCESS-ENVMON-MIB, CISCO-CALLHOME-MIB, CISCO-CONFIG-MAN-MIB, CISCO-FLASH-MIB, CISCO-ENTITY-SENSOR-MIB, IP-MIB, CISCO-PAGP-MIB  
Ports & interfaces
The number of basic switching RJ-45 Ethernet ports (sockets).  Basic switching RJ-45 Ethernet ports quantity 8  
The type/category of basic switching RJ-45 Ethernet ports (sockets).  Basic switching RJ-45 Ethernet ports type 10G Ethernet (100/1000/10000)  
Console port RJ-45  
Power connector AC-in jack  
Network
The way in which the network is working, e.g. IEEE 802.11a, IEEE 802.11b, IEEE 802.11g.  Networking standards IEEE 1588,IEEE 802.11ac,IEEE 802.11n,IEEE 802.1ab,IEEE 802.1p,IEEE 802.1s,IEEE 802.1w,IEEE 802.3,IEEE 802.3ab,IEEE 802.3ah,IEEE 802.3u,IEEE 802.3x  
Link aggregation Yes  
Broadcast storm control Yes  
Spanning tree protocol Yes  
Data transmission
The MAC address is the 'Media Access Control Address'. It is a unique address given to a network interface controller (NIC) in a device. A MAC address table shows the addresses in a table format.  MAC address table 8000 entries  
Number of queues 8  
Security
DHCP features DHCP snooping  
Access Control List (ACL) Yes  
Access Control List (ACL) IPv4 entries 2000  
Access Control List (ACL) IPv6 entries 512  
IGMP snooping Yes  
IGMP entries 1000  
Security algorithms are used to provide authentication, cipher key generation, integrity and radio link privacy to users on mobile networks. The security algorithms supported are the ones that can be used with this product.  Security algorithms 802.1x RADIUS  
Security access control method whereby the 48-bit address assigned to each network card is used to determine access to the network. MAC addresses are uniquely assigned to each card, so using MAC filtering on a network permits and denies network access to specific devices through the use of blacklists and whitelists.  MAC address filtering Yes  
BPDU filtering/protection Yes  
Authentication Guest VLAN  
Multicast features
Multicast support Yes  
Protocols
Management protocols IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PAgP, LACP VTPv2, VTPv3, EtherChannel, voice VLAN, PVST+, MSTP, and RSTP  
Switching protocols IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier  
Design
The type of mounting that can position devices in a shelving system (rack).  Rack mounting Yes  
The colour e.g. red, blue, green, black, white.  Product colour Black  
LED indicators Yes  
The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes".  International Protection (IP) code IP20  
DIN rail mounting Yes  
Certification UL, BSMI CNS 13438 Class A, CISPR 24, cUL, EN55022, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, NOM, VCCI Class A ITE, IEC 60950, EN55  
Performance
The amount of memory, usually measured in bytes (e.g. MB, GB), which is installed in the system's hardware.  Internal memory 4000 MB  MB
Flash memory 1500 MB  MB
Statistical model used to indicate product/mechanism reliability; expressed in hours and percentage of duty cycle. This number (in hours) does not indicate the mean time before failure for a single unit/mechanism.  Mean time between failures (MTBF) 3041040 h  
Power
There is a power supply with this product.  Power supply included Yes  
The voltage of the AC electricity that is inpitted into the product.  AC input voltage 120 - 230 V  
AC input frequency 50/60 Hz  
DC input voltage 9.6 - 60 V  
Input current 6.3 A  
Amount of power consumed by this model, often expressed in watts (W). Typical values that manufacturers give are power consumption when off, standby/suspended mode, typical use, maximum usage.  Power consumption (typical) 6 W  
Power over Ethernet (PoE)
The device supports Power over Ethernet (PoE), which is one of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras.  Power over Ethernet (PoE) No  
Operational conditions
The minimum and maximum temperatures at which the product can be safely operated.  Operating temperature (T-T) -40 - 70 °C  
The minimum and maximum temperatures at which the product can be safely stored.  Storage temperature (T-T) -40 - 85 °C  
Operating relative humidity (H-H) 5 - 95%  
Non-operating altitude 0 - 4572 m  
Weight & dimensions
The measurement or extent of something from side to side.  Width 152.4 mm  
The distance from the front to the back of something.  Depth 127 mm  
The measurement of the product from head to foot or from base to top.  Height 50.8 mm  
Packaging data
Cables included AC  
Manual Yes  
User guide Yes  

Chosen products
Stay in touch!
Join our newsletter and stay up to date with our promotions and news.

By clicking "Subscribe" you agree to receive marketing information at your e-mail address. Your personal data will be administered by Senetic Limited with its registered office in 7th Floor, Mulliner Towers, 39 Alfred Rewane Road, Ikoyi, Lagos, Nigeria. You have the right to demand access to personal data and to rectify, erase or limit the processing, as well as to object to the processing. Detailed information on the processing of personal data can be found in the privacy policy.

Incorrect e-mail address
This e-mail address has already been confirmed.
This e-mail address has not been confirmed yet.
Thank you!
Check your inbox - you will receive a message from us asking you to confirm your subscription to the newsletter.
Partnerships
Payment methods
Delivery methods
Certificates and awards